Nominal
Cond-
uctor
area |
Nominal
Thick-
ness
of
Insu-
lation |
Min. thick-ness
of inner
sheath |
Un armoured |
Armoured |
Max
Condu-ctor
Resi-stance
at 20° C |
Standard
Packing |
Nominal
outer
sheath
thick-ness |
Approx. Overall Diameter |
Apporx.
weight |
Nominal
Armour
Dime-nsion |
Min.
outer
sheath
thick-ness |
Approx. Overall Diameter |
Apporx.
weight |
sq.mm |
mm |
mm |
mm |
mm |
kg/km |
mm |
mm |
mm |
kg/km |
ohm/km |
m |
*1.5
*2.5
*4
*6
|
0.8
0.9
1.0
1.0
|
0.3
0.3
0.3
0.3
|
1.8
1.8
1.8
1.8
|
11.2
12.4
13.7
14.8
|
195
243
303
375
|
1.4
1.4
1.4
1.4
|
1.24
1.24
1.24
1.24
|
12.8
14.0
15.3
16.4
|
435
511
603
719
|
12.1
7.41
4.61
3.08
|
500±5%
500±5%
500±5%
500±5%
|
**1.5
**2.5
**4
**6
**10
**16
|
0.8
0.9
1.0
1.0
1.0
1.0
|
0.3
0.3
0.3
0.3
0.3
0.3
|
1.8
1.8
1.8
1.8
1.8
1.8
|
11.6
12.9
14.3
15.1
17.3
19.4
|
195
243
303
375
487
554
|
1.4
1.4
1.4
1.4
1.4
4x0.8
|
1.24
1.24
1.24
1.24
1.24
1.40
|
13.2
14.5
15.9
17.1
18.9
20.1
|
435
511
603
719
817
834
|
12.1
7.41
4.61
3.08
1.83
1.15
|
500±5%
500±5%
500±5%
500±5%
500±5%
500±5%
|
#25
#35
#50
#70
|
1.2
1.2
1.4
1.4
|
0.3
0.3
0.3
0.3
|
2.0
2.0
2.0
2.0
|
17.8
19.6
22.0
24.4
|
790
982
1282
1711
|
4x0.8
4x0.8
4x0.8
4x0.8
|
1.40
1.40
1.40
1.56
|
18.2
20.0
22.4
25.2
|
1111
1314
1617
2169
|
0.727
0.524
0.387
0.268
|
500±5%
500±5%
500±5%
500±5%
|
* Solid conductor **Stranded conductor #Shaped conductor
* Solid conductor **Stranded conductor #Shaped conductor
PVC - Insulated and PVC - Sheathed (heavy duty)
3 1/2 core Unarmourd(YY) and armourd (YWY/YFY) power cable with copper conductor for working voltages upto & including 1100 V to IS:1554 (Part 1) - 1988 |

|
Nominal
Cond-
uctor
area |
Nominal
Thick-
ness
of Insu-
lation |
Min. thick-ness
of inner
sheath |
Un armoured |
Armoured |
Max
Condu-ctor
Resi-stance
at 20° C
Fullcore/
Half core |
Standard
Packing |
Full
core |
Half core |
Nominal
outer
sheath
thick-ness |
Approx. Overall Dia-meter |
Apporx.
weight |
Nominal
Armour
Dime-nsion |
Min.
outer
sheath
thick-ness |
Approx. Overall Dia-meter |
Apporx.
weight |
sq.mm |
mm |
mm |
mm |
mm |
mm |
kg/km |
mm |
mm |
mm |
kg/km |
ohm/km |
m |
25/16
35/16
50/25
70/35
95/50
120/70
150/70
185/95
|
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
|
1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
|
0.3
0.3
0.3
0.4
0.4
0.5
0.5
0.5
|
2.0
2.0
2.0
2.2
2.2
2.4
2.4
2.6
|
23.2
25.6
27.8
30.4
34.4
38.2
42.0
45.9
|
1303
1621
2114
2936
3880
4861
5684
8963
|
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
|
1.40
1.40
1.56
1.56
1.56
1.72
1.88
2.04
|
23.6
26.0
28.2
30.6
34.6
38.4
42.4
46.3
|
1689
2054
2658
3497
4397
5510
6486
9826
|
0.727/1.15
0.524/1.15
0.387/0.727
0.268/0.524
0.193/0.387
0.153/0.268
0.124/0.268
0.0991/0.193
|
500±5%
500±5%
500±5%
500±5%
500±5%
500±5%
250±5%
250±5%
|
All siezes - Shaped conductor
PVC - Insulated and PVC - Sheathed (heavy duty)
4 core Unarmourd(YY) and armourd (YWY/YFY)
power cable with copper conductor for working voltages
upto & including 1100 V to IS:1554 (Part 1) - 1988 |

|
Nominal
Cond-
uctor
area |
Nominal
Thick-
ness
of
Insu-
lation |
Min. thick-ness
of inner
sheath |
Un armoured |
Armoured |
Max
Condu-ctor
Resi-stance
at 20° C |
Standard
Packing |
Nominal
outer
sheath
thick-ness |
Approx. Overall Dia-meter |
Apporx.
weight |
Nominal
Armour
Dime-nsion |
Min.
outer
sheath
thick-ness |
Approx. Overall Dia-meter |
Apporx.
weight |
sq.mm |
mm |
mm |
mm |
mm |
kg/km |
mm |
mm |
mm |
kg/km |
ohm/km |
m |
*1.5
*2.5
*4
*6
|
0.8
0.9
1.0
1.0
|
0.3
0.3
0.3
0.3
|
1.8
1.8
1.8
1.8
|
12.5
13.9
15.5
16.9
|
255
328
423
540
|
1.4
1.4
1.4
1.4
|
1.24
1.24
1.24
1.24
|
14.1
15.5
17.1
18.5
|
523
635
769
921
|
12.1
7.41
4.61
3.08
|
500±5%
500±5%
500±5%
500±5%
|
**1.5
**2.5
**4
**6
**10
**16
|
0.8
0.9
1.0
1.0
1.0
1.0
|
0.3
0.3
0.3
0.3
0.3
0.3
|
1.8
1.8
1.8
1.8
1.8
2.0
|
12.9
14.5
16.2
17.7
19.8
22.7
|
255
328
428
540
728
974
|
1.4
1.4
1.4
1.4
4x0.8
4x0.8
|
1.24
1.24
1.24
1.24
1.40
1.40
|
14.5
16.1
17.8
19.7
20.6
23.1
|
523
635
769
921
1051
1281
|
12.1
7.41
4.61
3.08
1.83
1.15
|
500±5%
500±5%
500±5%
500±5%
500±5%
500±5%
|
#25
#35
#50
#70
#95
#120
#150
#185
|
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
|
0.3
0.3
0.4
0.4
0.4
0.5
0.5
0.6
|
2.0
2.0
2.2
2.2
2.2
2.4
2.6
2.8
|
23.1
25.4
29.8
34.4
37.0
40.6
45.8
50.3
|
1417
1804
2384
3273
4358
5409
6589
8184
|
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
|
1.40
1.40
1.56
1.56
1.72
1.72
1.88
2.04
|
23.5
25.8
30.0
34.6
37.6
40.8
46.1
50.5
|
1806
2210
2892
3832
4977
6102
7384
9070
|
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
|
500±5%
500±5%
500±5%
500±5%
500±5%
500±5%
250±5%
250±5%
|
* Solid conductor **Stranded conductor #Shaped conductor
CLICK HERE TO VISIT:
POWER CABLES - AS PER IS:1554
POWER CABLES – AS PER BS:6346:1989
PVC INSULATED ARMOURED / UNARMOURED CABLES TO BS 6346:1989
Conductor
Copper conductors are made from high conductivity Copper rods of 8 mm diameter. The rod is drawn to required sizes for the construction of conductors of different areas of cross section conforming to SS 6360.
Conductors for Power cables with cross sectional area up to 16 sq.mm are either solid circular or stranded circular (non-compact) conforming to Table 1 Class 1 or Table 2 Class 2 of SS 6360. Conductors for Power Cables with cross sectional area 25 sq.mm. and above are stranded shaped conforming to Table 2 Class 2 of BS:6360.
Insulation
PVC Compound is insulated over conductor by extrusion process with required thickness of insulation and conforms to BS:6346:1989.
PVC insulation, is of type TI 1 PVC compound conforming to BS 6746:1990, suitable for a continuous conductor operating temperature not exceeding 70°C.
Identification of core colours:
| No. of cores |
Identification |
1 |
Red or Black |
2 |
Red and Black |
3 |
Red, Yellow and Blue |
4 |
Red, Yellow, Blue and Black |
Laying up
Cores are laid up with right hand lay in the outermost layer in the sequence of above core colours. Interstices, if necessary, are covered with non hygroscopic fillers and covered with a binder tape for compactness and to maintain reasonably round shape.
Bedding
All multi-core cables of nominal area less than 10 sq.mm have extruded bedding. Cables having nominal area 10 sq.mm and above have either extruded PVC bedding or 2 or more layers of PVC or other synthetic tape, which is compatible to insulation material and removable without any damage to insulation. Single core armoured cables have extruded PVC bedding.
Armouring
Single core cables for use on A.C systems, are armoured with single layer of aluminium wires. Multi-core armoured cables have single layer of Galvanized Steel wire Armour over bedding with left hand lay.
Other armours like steel strip, tape can also be provided against customer specification.
Oversheath
Sheaths are extruded with Black PVC compound of type TM 1 and comply with the requirements of BS 6746:1990. When specified anti termite properties can be provided on the sheath.
Packing, storage and handling
Cables for power supplies are always packed in appropriate sizes of strong and seasoned wooden drums designed to withstand long distance transit and preservation in stores.
Power cables of all sizes of single core, Power cables of multi-cores upto 120 sq.mm. are packed in standard lengths of 500 metre + 5% and Power cables of multi-cores of 150 sq.mm. and above are packed in standard lengths of 250 metre + 5%. It is advised that drums are always to be stored in concrete floors to avoid sinking in mud and damages or deterioration of drum flanges and shall not be stored on its flanges horizontal to ground. Drums are designed for easy handling when transported by cranes or mounted on cable drum wheels for laying. Cables in drums shall be stored away from boilers and furnaces.
Customer orientation
Against specific requirement and application, Q-Flx Wires & Cables can offer cables conforming to either customer specification or other National and International Standards.
Current ratings
Current ratings of cables installed in air and around buildings reference should be made to'Regulations for electrical installations' (IEE Wiring Regulations), 15th Edition and the current ratings of cables installed in other situations reference should be made to 'Current rating standards for distribution cables', ERA 69-30:Part Ill.
Minimum installation radius
Circular copper conductors, unarmoured
Circular copper conductor, armoured
Shaped copper conductors armoured or unarmoured |
upto 10 mm overall diameter = 3D
above 10 mm and upto 25 mm overall diameter = 4D
above 25 mm overall diameter = 6D
any overall diameter = 6D
any overall diameter = 8D |
Conditions of laying
1. Continuous operating temperature of conductor 70° C
2. Ambient Temperature 50° C
3. Ground Temperature 35°C
4. Depth of laying in ground 0.5 m
5. Thermal resistivity of ground 120° C cm/W
PVC Insulated and PVC sheathed single core unarmoured cable
with copper conductor 600 / 1000 V to IEC 502 : 1994
Nominal Conductor Area |
Thickness of Insulation |
Thickness of Oversheath |
Approx. Overall Diameter |
Approx.
Cable Weight |
Maximum Conductor Resistance At 20° C |
Standard Packing |
Sq.mm |
mm |
mm |
mm |
kg/km |
ohm/km |
m |
1
1.5
2.5
4
6
10
16
25
35
|
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
|
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
|
6.4
6.8
7.2
8.2
8.7
9.6
10.9
12.5
13.5
|
50
60
75
100
125
170
235
335
440
|
18.1
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
|
100
100
100
100
100
100
100
100
100
|
PVC Insulated and PVC sheathed single core unarmoured and
armoured cable with copper conductor 600 / 1000 V to IEC 502 : 1994
Nominal
Con-
ductor
Area |
Thick-
ness
of
Insu-
lation |
Unarmoured |
armoured |
Maxi-
mum Condu-
ctor Resis-
tance At 20° C |
Standard Packing |
Thick-
ness
of
Over
sheath |
Approx. Overall Dia-
meter |
Approx.
Cable Weight |
Thick-
ness
of
Extruded
Bedding |
Diameter
of
Armour
Wire |
Thickness
of Over
sheath |
Approx. Overall Dia-
meter |
Approx.
Cable Weight |
Sq.mm |
mm |
mm |
mm |
kg/km |
mm |
mm |
mm |
mm |
kg/km |
ohm/km |
m |
50
70
95
120
150
185
|
1.4
1.4
1.6
1.6
1.8
2.0
|
1.4
1.4
1.5
1.5
1.6
1.7
|
15.1
16.9
19.4
21.0
23.2
25.8
|
580
790
1090
1340
1360
2080
|
0.8
0.8
0.8
1.0
1.0
1.0
|
1.25
1.25
1.25
1.6
1.6
1.6
|
1.5
1.6
1.6
1.7
1.7
1.8
|
19.1
21.1
23.4
26.3
28.3
30.8
|
820
1070
1390
1690
1960
2450
|
0.387
0.268
0.193
0.153
0.124
0.0991
|
500±5%
500±5%
500±5%
500±5%
500±5%
500±5% |
PVC Insulated and PVC sheathed 2 core unarmoured and armoured cable with copper conductor 600 / 1000 V to BS 6346 : 1989 |

|
Nominal
Con-
ductor
Area |
Thick-
ness
of
Insu-
lation |
Unarmoured |
armoured |
Maxi-
mum Condu-
ctor Resis-
tance At 20° C |
Standard Packing |
Thick-
ness
of
Over
sheath |
Approx. Overall Dia-
meter |
Approx.
Cable Weight |
Thick-
ness
of
Extruded
Bedding |
Diameter
of
Armour
Wire |
Thickness
of Over
sheath |
Approx. Overall Dia-
meter |
Approx.
Cable Weight |
Sq.mm |
mm |
mm |
mm |
kg/km |
mm |
mm |
mm |
mm |
kg/km |
ohm/km |
m |
1.5
2.5
4
6
10
16
25
35
50
70
|
0.6
0.7
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
|
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
|
9.5
9.8
11.5
12.8
16.1
18.6
18.4
20.1
22.8
25.5
|
130
190
240
310
450
600
820
1040
1250
1670
|
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
|
0.9
0.9
0.9
0.9
1.25
1.25
1.6
1.6
1.6
1.6
|
1.3
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
1.9
|
11.7
13.1
15.1
16.5
20.1
21.9
23.0
24.9
27.8
30.4
|
325
390
490
580
840
990
1480
1770
1900
2430
|
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
|
500±5%
500±5%
500±5%
500±5%
500±5%
500±5%
500±5%
500±5%
500±5%
500±5%
|
Thickness of oversheath and approximate overall diameter of unarmoured cables 1.5 sq. mm - 6 sq. mm are conforming to
IEC 502 : 1994. 1.5 & 2.5 sq. mm cables are with circular solid conductors. However, cables with circular stranded conductors can also be offered |
PVC Insulated and PVC sheathed 3 core unarmoured
and armoured cable with copper
conductor 600 / 1000 V to BS 6346 : 1989 |

|
Nominal
Con-
ductor
Area |
Thick-
ness
of
Insu-
lation |
Unarmoured |
armoured |
Maxi-
mum Condu-
ctor Resis-
tance At 20° C |
Standard Packing |
Thick-
ness
of
Over
sheath |
Approx. Overall Dia-
meter |
Approx.
Cable Weight |
Thick-
ness
of
Extruded
Bedding |
Diameter
of
Armour
Wire |
Thickness
of Over
sheath |
Approx. Overall Dia-
meter |
Approx.
Cable Weight |
Sq.mm |
mm |
mm |
mm |
kg/km |
mm |
mm |
mm |
mm |
kg/km |
ohm/km |
m |
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
|
0.6
0.7
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
|
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.1
2.2
2.3
2.5
|
10.0
11.4
13.2
14.6
17.0
19.7
20.4
22.4
25.5
28.7
33.3
36.3
40.0
44.6
|
110
160
225
330
470
655
955
1250
1665
2295
3145
3890
4760
5950
|
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
|
0.9
0.9
0.9
1.25
1.25
1.25
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
|
1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.4
2.5
|
12.3
13.6
15.8
18.0
21.2
23.1
25.0
27.3
30.5
35.0
39.3
42.2
47.5
51.9
|
307
387
493
701
967
1219
1614
1992
2534
3518
4510
5375
6810
8190
|
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
|
500±5%
500±5%
500±5%
500±5%
500±5%
500±5%
500±5%
500±5%
500±5%
500±5%
500±5%
500±5%
250±5%
250±5%
|
Thickness of oversheath and approximate overall diameter of unarmoured cables 1.5 sq. mm - 6 sq. mm are conforming to
IEC 502 : 1994. 1.5 & 2.5 sq. mm cables are with circular solid conductors. However, cables with circular stranded conductors can also be offered. |
PVC Insulated and PVC sheathed 4 core unarmoured
and armoured cable with copper conductor
600 / 1000 V to BS 6346 : 1989 |

|
Nominal Conductor Area |
Thickness of Insulation |
Unarmoured |
Armoured |
Maximum Conductor Resistance at 20. C |
Standard Packing |
Thickness of Over Sheath |
Approx. Overall Diameter |
Approx. Cable Weight |
Thickness of Extruded bedding |
Diameter of Armour Wire |
Thickness of Over Sheath |
Approx. overall Diameter |
Approx. cable weight. |
Phase |
Neutral |
Phase |
Neutral |
|
|
|
|
|
|
|
|
Phase |
Neutral |
|
Sq.mm |
Sq.mm |
Mm |
Mm |
Mm |
Mm |
Kg/km |
Mm |
Mm |
Mm |
Mm |
Kg/km |
Ohm/km |
Ohm/km |
m |
25 |
16 |
1.2 |
1.0 |
1.8 |
22.9 |
1270 |
1.0 |
1.6 |
1.8 |
27.8 |
1900 |
0.727 |
1.15 |
500+5 % |
35 |
16 |
1.2 |
1.0 |
1.8 |
24.7 |
1620 |
1.0 |
1.6 |
1.8 |
29.5 |
2300 |
0.524 |
1.15 |
500+5 % |
50 |
25 |
1.4 |
1.2 |
1.9 |
28.3 |
2140 |
1.0 |
1.6 |
1.9 |
33.1 |
3050 |
0.387 |
0.727 |
500+5 % |
70 |
35 |
1.4 |
1.2 |
2.0 |
32.0 |
2900 |
1.2 |
2.0 |
2.0 |
38.0 |
4130 |
0.268 |
0.524 |
500+5 % |
95 |
50 |
1.6 |
1.4 |
2.1 |
37.5 |
3940 |
1.2 |
2.0 |
2.2 |
43.7 |
5370 |
0.193 |
0.387 |
500+5 % |
120 |
70 |
1.6 |
1.4 |
2.2 |
41.4 |
4900 |
1.4 |
2.5 |
2.3 |
49.0 |
6840 |
0.153 |
0.268 |
500+5 % |
150 |
70 |
1.8 |
1.4 |
2.4 |
44.7 |
5900 |
1.4 |
2.5 |
2.4 |
52.0 |
8040 |
0.124 |
0.268 |
250+5 % |
185 |
95 |
2.0 |
1.6 |
2.5 |
49.9 |
7420 |
1.4 |
2.5 |
2.5 |
57.2 |
9760 |
0.0991 |
0.193 |
250+5 % |
Current rating of PVC insulated cables with copper conductor 600 /1000 V
armoured and unarmoured to BS: 6346 : 1989
Conductor
Size |
Armoured |
Unarmoured |
In Air |
In Ground |
In Air |
1 Core |
2 Core |
3 Core |
1 Core |
2 Core |
3 Core |
1 Core |
2 Core |
3 Core |
Sq. mm |
A |
A |
A |
A |
A |
A |
A |
A |
A |
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
|
22
33
42
53
69
90
117
143
201
252
306
353
398
449
|
20
28
36
47
64
85
112
137
166
209
258
298
338
391
|
16
23
31
38
54
72
95
113
145
179
220
256
294
336
|
33
48
62
77
99
126
162
197
241
297
354
398
439
489
|
29
40
53
68
91
118
157
188
223
278
333
378
423
479
|
26
34
47
57
77
100
130
153
190
231
277
315
351
398
|
20
30
39
49
59
86
111
138
195
246
303
353
404
466
|
18
24
33
42
59
81
107
131
160
201
250
290
333
384
|
16
22
29
37
52
70
91
112
145
174
214
250
285
329
|
When installed in air cables are spaced between centres twice the diameter of cable
When laid in ground cables are touching together |
A.C. Resistance and Reactance
Nominal Conductor
area |
Resistance |
Resistance |
*Single
core
|
Multi
Core
|
*Single core |
Multi Core |
Trefoil |
Flat |
|
Sq.mm |
Ohm/Km |
Ohm/Km |
Ohm/Km |
Ohm/Km |
Ohm/Km |
1.0
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
|
22.72
15.19
9.3
5.79
3.87
2.30
1.44
0.913
0.658
0.486
0.337
0.243
0.193
0.159
0.126
|
-
15.9
9.30
5.79
3.87
2.30
1.44
0.913
0.658
0.486
0.337
0.243
0.193
0.159
0.126
|
-
-
-
-
-
-
-
0.121
0.116
0.115
0.112
0.107
0.103
0.101
0.099
|
-
-
-
-
-
-
-
0.210
0.202
0.201
0.195
0.188
0.186
0.185
0.184
|
0.116
0.115
0.111
0.096
0.092
0.091
0.086
0.086
0.083
0.080
0.077
0.077
0.075
0.075
0.074
|
| *Aluminium wire armoured cable |